This article explains complete direct cool refrigerator wiring, including thermostat terminals, Danfoss relay, light circuit, heater, and door switch. The clean diagram makes troubleshooting and repairing even easier for technicians and students.
Direct Cool Refrigerator Wiring Diagram 1
Direct Cool Refrigerator Wiring Diagram 2
How the Main Wire Supplies Power
The main wire carries live and neutral supply from the plug to the internal components. Live usually travels through the thermostat and relay, while neutral directly connects to the compressor, heater, and light.
Thermostat Terminal Explanation (3 – 6 – 4)
The thermostat controls compressor ON/OFF according to cooling demand.
-
Terminal 3: Incoming live supply
-
Terminal 6: Output to relay
-
Terminal 4: Heater/light control (depending on model)
When the fridge warms up, the thermostat closes the circuit and sends power to the relay.
Danfoss Relay and Overload Protector
The Danfoss relay activates the compressor’s start and run windings. The overload protector prevents compressor damage from overheating or high current. These components must be wired correctly for stable cooling performance.
Light Bulb & Door Switch Wiring
The door switch disconnects the light whenever the door is closed. When you open the door, the switch allows live power to reach the bulb. This simple circuit ensures proper illumination inside the fridge.
Defrost Heater Wiring
The heater prevents ice buildup on the evaporator. It receives power through the thermostat or defrost control. Correct heater wiring ensures smooth cooling without frost formation.
haier refrigerator direct cool wiring diagram
Clean and accurate wiring improves safety, reduces component failure, and makes troubleshooting faster. A properly recreated diagram helps beginners understand the complete flow of electricity inside the refrigerator.
Conclusion
Direct cool refrigerator wiring is simple but essential to understand. With the right diagram and proper knowledge of thermostat, relay, heater, and light connections, any technician can diagnose and repair problems easily.